Support

Need Support? We’ve got you covered.

SafeSync™ is built for reliability, but we know questions come up. Whether you need a quick troubleshooting tip or a full manual, this page is your hub for resources. Call or email our team for warranty and technical support, or explore the guides and videos below.

Manuals & Guides

Download everything you need to keep your SafeSync™ system running smoothly.

Spec Sheet

SafeSync™ Manual

What is SafeSync™ Service Mode?

Patent-Pending Height Limit Feature

Troubleshooting

Not sure what’s wrong? Start here.

SafeSync may limit or block functions when unsafe conditions are detected. This is normal and designed to protect the operator and equipment.

  • “Open Load” or “Over Load” typically indicates a wiring issue in the system.
  • Start by checking the wiring and connections using the diagram in your manual (page 39). If a fault is present, it will appear highlighted on the diagnostic screen.
  • If no issue is visible and the error continues, contact technical support for further assistance.
  • A fuse error usually indicates a wiring or electrical issue in that circuit.
  • Use the fuse/relay diagram in your operator manual (pages 56-57) to locate the affected fuse. Inspect the fuse and related wiring, and repair or replace as needed.
  • SafeSync displays error codes to help identify and resolve issues quickly.
  • Follow the on-screen instructions to correct the condition. For more details, refer to Appendix B in the IQAN User Manual.
  • Service Mode allows limited operation in certain failure conditions.
  • To enter this mode, follow the instructions in your operator manual (page 38).
  • Use this mode only when necessary to safely move or unload the truck.
  • Once the issue has been addressed, the system should be returned to normal operation.
  • Follow the instructions in your operator manual (page 38). The truck should be inspected before returning to regular use.
  • Check the SafeSync display for any active warnings or error messages. If a system-related issue is present, it will be shown on the screen.
  • If no errors are displayed, the issue may be mechanical (such as hydraulics, PTO, pump, valve, or actuator). Refer to your truck or body manual for mechanical troubleshooting, or contact your service provider.
  • If SafeSync detects an unsafe condition, it will block operation and display a warning message.
  • Check the screen for any active alerts and follow the instructions provided. If no warning is present, the issue may be mechanical and should be inspected by a technician.
  • First, check the SafeSync display for any error messages or warnings.
  • If no error is shown, inspect the components and connections. For cameras, check the Ethernet cable and connections. For lights, check wiring and power supply.
  • If everything appears connected properly and the issue persists, contact technical support.
  • This message indicates that SafeSync is not communicating with the specified component.
  • Start by checking power and ground connections for that component (see manual page 39).
  • If power is confirmed, this may indicate a CAN communication issue. Access the system schematic from the control screen—any disconnected component will be highlighted. Check connections and repair as needed.
  • SafeSync limits operation when it detects conditions that could be unsafe or damaging.
  • This may include excessive speed, steep slope or grade, or reaching a preset height or angle limit. Return to safe conditions or adjust settings (if authorized) before continuing.
  • SafeSync is designed to prevent unsafe operation, but in certain situations, authorized users can access override functions through protected settings. Overrides should only be used when necessary and with proper understanding of the risks involved.
  • SafeSync may be detecting an unsafe condition.
  • Check that the tarp is not deployed, the truck is within speed limits, and you’re on a safe slope or grade.
  • Clear the condition and try again.
  • The PTO may have reached a preset RPM or speed limit.
  • Reduce engine RPM or vehicle speed, then re-engage the PTO once conditions are safe.
  • SafeSync issues warnings when it detects conditions that could be unsafe or damaging.
  • Follow the on-screen message to correct the issue before continuing.
  • The tarp will not deploy if the body is raised, the tailgate is positioned incorrectly, or the truck is over the speed limit.
  • Return to safe conditions and try again.

Frequently Asked Questions

Download everything you need to keep your SafeSync™ system running smoothly.

SafeSync has two levels of settings designed for different users:

  • Quick Truck User Adjustments: These can be changed by the operator and are accessed by selecting the tools icon in the lower right corner of the touchscreen.
  • Truck User Defined Settings: These are password-protected and intended for supervisors or owners. This menu allows adjustment of system limits and safety features that affect how the truck operates.
  • The password can be retrieved by contacting SafeSync customer support.
  • Once accessed, supervisors or owners can update the password. After it is changed, managing the password is the responsibility of the owner or fleet.
  • No. The SafeSync display is standardized to ensure consistent operation and clear visibility for all users.
  • Screen brightness and display settings can be adjusted through the system menu:
    • Select the Menu button
    • Navigate to Cab Display
    • Select Adjust
    • Modify day/night brightness and keypad sound settings as needed
  • SafeSync supports remote diagnostics through the IQAN Go app. (Download from the Apple App Store or Google Play)
  • To connect:
    • Open the system menu and navigate to the module settings:
      • Menu → Cab Display → System → Modules
      • Select the truck-mounted module
      • Locate the pairing passkey
    • Connect to the system using IQAN Go
    • Select Remote Assistance in the app
    • Provide the access code to your support representative
  • Once connected, the technician can diagnose the system remotely. Do not exit the app while support is connected.
  • SafeSync is sold and installed through TBEI brands, including OSW Equipment, Ox Bodies, J-Craft, and DuraClass. To connect with your local sales team, visit our Contact page.
  • SafeSync is primarily offered as part of a truck upfit through TBEI brands. Contact our sales team to discuss availability and options for your specific application.
  • SafeSync is backed by TBEI’s warranty and service network.
  • For full warranty details or to submit a claim, visit our Support page or contact our team.
  • SafeSync is a smart dump body control system designed to improve safety, simplify operation, and protect equipment. It uses intelligent interlocks, real-time alerts, and intuitive controls to help prevent unsafe actions on the job site.
  • SafeSync is designed for dump truck fleets, operators, and dealers who prioritize safety, reliability, and consistent operation across their equipment.
  • SafeSync is designed for Class 8 dump trucks and is available through TBEI upfit brands. Contact our team to confirm compatibility for your specific configuration.
  • Yes. SafeSync includes both a touchscreen and tactile buttons, allowing operators to use the system with or without gloves.
  • Yes. These limits can be adjusted by authorized users in the Truck User Defined Settings menu.
  • Refer to the operator manual (page 47) for more information.
  • Only supervisors or owners with the password can access and adjust system settings that affect safety limits and operation.
  • SafeSync is primarily offered as part of new truck upfits through TBEI brands. Availability for retrofitting may vary depending on the truck and configuration. Contact our team to discuss options for your fleet.
  • SafeSync helps reduce costs by preventing unsafe operation that can lead to equipment damage, downtime, and job site incidents. With built-in interlocks and operator alerts, it helps fleets avoid costly mistakes before they happen.
  • Yes. By limiting improper use—like PTO operation outside safe limits or operating in unsafe conditions—SafeSync helps protect key components from unnecessary wear and damage, extending the life of your equipment.
  • SafeSync helps standardize how dump body operations are performed across your fleet. Clear controls, visual feedback, and built-in safeguards reduce guesswork, making it easier for both new and experienced operators to use equipment safely and consistently.
  • Insurance impacts can vary by provider and fleet. However, systems like SafeSync that reduce risk and improve safety practices may support conversations around insurance costs. We recommend discussing this directly with your insurance provider.
  • This function overrides warnings and interlocks in the case that you need to remove a load and the system is preventing the operation due to a malfunction. ONLY use this function to safely remove the load, then return to standard mode and take the truck for service immediately. An administrator can enable Service Mode at any time. Learn more about Service Mode by clicking here.
  • SafeSync is designed to prevent unsafe operation, but in certain situations, authorized users can access override functions through protected settings. Overrides should only be used when necessary and with proper understanding of the risks involved.
  • SafeSync is designed for long-term reliability with minimal maintenance. Routine inspections as part of your standard vehicle maintenance program are recommended. Software updates or adjustments can be performed as needed through service tools.

Warranty & Support

SafeSync is supported by the comprehensive warranty and terms and conditions of the brand you purchase it through as part of your truck upfit. Please refer to your upfit provider for full warranty details and coverage information. For warranty claims and technical questions, contact us below. For parts or other inquiries, contact your brand.

Support Hours: 8:00 A.M. – 4:30 P.M. Central

Ready to protect your fleet—and your bottom line?